CPU COD. X20CP1483
INTERFACES: 1x RS232, 1x ETHERNET, 1x POWERLINK V1/V2, 2x USB, 1x X2X LINK
SYSTEM MODULE: CPU
COOLING: FANLESS
STATUS INDICATORS: CPU FUNCTION, ETHERNET, POWERLINK, COMPACTFLASH, BATTERY
DIAGNOSTIC (BATTERY): YES, USING LED STATUS INDICATOR AND SOFTWARE
DIAGNOSTIC (CPU FUNCIOTN): YES, USING LED STATUS INDICATOR
DIAGNOSTIC (COMPACTFLASH): YES, USING LED STATUS INDICATOR
DIAGNOSTIC (ETHERNET): YES, USING LED STATUS INDICATOR
DIAGNOSTIC (POWERLINK): YES, USING LED STATUS INDICATOR
DIAGNOSTIC (TEMPERATURE): YES, USING SOFTWARE REGISTER
SUPPORT (ACOPOS): YES
SUPPORT (VISUAL COMPONENTS): YES
POWER CONSUMPTION WITHOUT MEMORY CARD, INTERFACE MODUE AND USB: 6 W
POWER CONSUMPTION FOR X2X LINK POWER SUPPLY: 1.42 W
POWER CONSUMPTION (INTERNAL I/O): 0.6 W
CERTIFICATION CE: YES
CERTIFICATION UKCA: YES
CERTIFICATION ATEX: ZONE 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (SEE X20 USER'S MANUAL) FTZÚ 09 ATEX 0083X
CERTIFICATION UL: cULus E115267 INDUSTRIAL CONTROL EQUIPMENT
CERTIFICATION HAZLOC: cCSAus 244665 PROCESS CONTROL EQUIPMENT FOR HAZARDOUS LOCATIONS CLASS I, DIVISION 2, GROUPS ABCD, T5
CERTIFICATION DNV: TEMPERATURE B (0 -55°C), HUMIDITY B (FINO AL 100%), VIBRATION B (4g), EMC B (BRIDGE AND OPEN DECK)
CERTIFICATION LR: ENV1
CERTIFICATION KR: YES
CERTIFICATION ABS: YES
CERTIFICATION EAC: YES
CERTIFICATION KC: YES
CPU AND X2X LINK POWER SUPPLY (INPUT VOLTAGE): 24 VDC -15% / +20%
CPU AND X2X LINK POWER SUPPLY (INPUT CURRENT): MAX. 2.2 A
CPU AND X2X LINK POWER SUPPLY (FUSE): INTEGRADETD, CANNOT BE REPLACED
CPU AND X2X LINK POWER SUPPLY (REVERSE POLARITY PROTECTION): YES
X2X LINK POWER SUPPLY OUTPUT (NOMINAL OUTPUT POWER): 7 W
X2X LINK POWER SUPPLY OUTPUT (PARALLEL CONNECTION): YES
X2X LINK POWER SUPPLY OUTPUT (REDUNDANT OPERATION): YES
INPUT I/O POWER SUPPLY (INPUT VOLTAGE): 24 VDC -15% / +20%
INPUT I/O POWER SUPPLY (FUSE): REQUIRED LINE FUSE (MAX. 10 A, SLOW-BLOW)
OUTPUT I/O POWER SUPPLY (NOMINAL OUTPUT VOLTAGE): 24 VDC
OUTPUT I/O POWER SUPPLY (PERMISSIBLE CONTACT LOAD): 10 A
POWER SUPPLY - GENERAL INFORMATION (STATUS INDICATORS): OVERLOAD, OPERATING STATUS, MODULE STATUS, RS232 DATA TRANSFER
POWER SUPPLY - GENERAL INFORMATION (DIAGNOSTIC - RS232 DATA TRANSFER): YES, USING LED STATUS INDICATOR
POWER SUPPLY - GENERAL INFORMATION (DIAGNOSTIC - MODULE RUN/ERROR): YES, USING LED STATUS INDICATOR AND SOFTWARE
POWER SUPPLY - GENERAL INFORMATION (DIAGNOSTIC - OVERLOAD): YES, USING LED STATUS INDICATOR AND SOFTWARE
POWER SUPPLY - GENERAL INFORMATION (ELECTRICAL ISOLATION - I/O SUPPLY - I/O POWER SUPPLY): NO
POWER SUPPLY - GENERAL INFORMATION (ELECTRICAL ISOLATION - CPU/X2X LINK SUPPLY - CPU/X2X LINK POWER SUPPLY): YES
CONTROLLER (COMPACTFLASH SLOT): 1
CONTROLLER (REAL-TIME CLOCK): NONVOLATILE, RESOLUTION 1s, -10 TO 10 PPM ACCURANCY AT 25°C
CONTROLLER (FPU): YES
CONTROLLER (PROCESSOR TYPE): x86 100 (COMPATIBLE)
CONTROLLER (CLOCK FREQUENCY): 100 MHz
CONTROLLER (L1 CACHE FOR DATA AND PROGRAM CODE): 16 kB
CONTROLLER (INTEGRATED I/O PROCESSOR): PROCESS I/O DATA POINTS IN THE BACKGROUND
CONTROLLER (MODULAR INTERFACE SLOTS): 1
CONTROLLER (REMANENT VARIABLES): MAX. 32 kB
CONTROLLER (SHORTEST TASK CLASS CYCLE TIME): 1 mS
CONTROLLER (TYPICAL INSTRUCTION CYCLE TIME): 0.09 µs
CONTROLLER (DATA BUFFERING - BATTERY MONITORING): YES
CONTROLLER (DATA BUFFERING - LITHIUM BATTERY): AT LEAST 3 YEARS
CONTROLLER (STANDARD MEMORY - RAM): 32 MB SDRAM
CONTROLLER (STANDARD MEMORY - USER RAM): 128 kB SRAM
INTERFACE IF1 (Type): RS232
INTERFACE IF1 (VARIANT): CONNECTION VIA 12-PIN TERMINAL BLOCK TB12
INTERFACE IF1 (MAX. DISTANCE): 900m
INTERFACE IF1 (TRANSFER RATE): MAX. 115.2 kbit/s
INTERFACE IF2 (TYPE): ETHERNET
INTERFACE IF2 (VARIANT): 1x RJ45 SHIELDED
INTERFACE IF2 (LINE LENGTH): MAX. 100m BETWEEN 2 STATIONS (SEGMENT LENGTH)
INTERFACE IF2 (TRANSFER RATE): 10/100 Mbit/s
INTERFACE IF2 (TRANSFER - PHYSICAL LAYER): 10BASE-T/100BASE-TX
INTERFACE IF2 (TRANSFER - HALF-DUPLEX): YES
INTERFACE IF2 (TRANSFER - FULL-DUPLEX): YES
INTERFACE IF2 (TRANSFER - AUTONEGOTIATION): YES
INTERFACE IF2 (TRANSFER - AUTO-MDI/MDIX): YES
INTERFACE IF3 (FIELDBUS): POWERLINK V1/V2 (MANAGING OR CONTROLLED NODE)
INTERFACE IF3 (TYPE): TYPE 4
INTERFACE IF3 (VARIANT): 1x RJ45 SHIELDED
INTERFACE IF3 (LINE LENGTH): MAX. 100m BETWEEN 2 STATIONS (SEGMENT LENGTH)
INTERFACE IF3 (TRANSFER RATE): 100 Mbit/s
INTERFACE IF3 (TRANSFER - PHYSICAL LAYER): 100BASE-TX
INTERFACE IF3 (TRANSFER - HALF-DUPLEX): YES
INTERFACE IF3 (TRANSFER - FULL-DUPLEX): POWELINK MODE: NO / ETHERNET MODE: YES
INTERFACE IF3 (TRANSFER - AUTONEGOTIATION): YES
INTERFACE IF3 (TRANSFER - AUTO-MDI/MDIX): YES
INTERFACE IF4 (TYPE): USB 1.1
INTERFACE IF4 (VARIANT): TYPE A
INTERFACE IF4 (MAX. OUTPUT CURRENT): 0.5 A
INTERFACE IF5 (TYPE): USB 1.1
INTERFACE IF5 (VARIANT): TYPE A
INTERFACE IF5 (MAX. OUTPUT CURRENT): 0.5 A
INTERFACE IF6 (FIELDBUS): X2X LINK MASTER
ELECTRICAL ISOLATION: ETHERNET (IF2), POWERLINK (IF3) AND X2X (IF6) ISOLATED FROM EACH OTHER, FROM OTHER INTERFACES AND FROM PLC
MOUNTING ORIENTATION (HORIZONTAL): YES
MOUNTING ORIENTATION (VERTICAL): YES
INSTALLATION ELEVATION ABOVE SEA LEVEL (0 TO 2000m): NO LIMITATION
INSTALLATION ELEVATION ABOVE SEA LEVEL (>2000mt): REDUCTION OF AMBIENT TEMPERATURE BY 0.5°C PER 100m
DEGREE PROTECTION PER EN 60529: IP20
TEMPERATURE (OPERATION IN HORIZONTAL MOUNTING): -25 TO 60°C
TEMPERATURE (OPERATION IN VERTICAL MOUNTING): -25 TO 50°C
TEMPERATURE (STORAGE AND TRANSPORT): -40 TO 85°C
RELATIVE HUMIDITY (OPERATION, STORAGE AND TRANSPORT): 5 TO 95%, NON-CONDENSING
NOTE: ORDER APPLICATION MEMORY (COMPACTFLASH) SEPARATELY. BACKUP BATTERY, X20 END COVER PLATE (RIGHT), 12-PIN X20 TERMINAL BLOCK AND INTERFACE MODULE SLOT COVERS INCLUDED IN DELIVERY
DIMENSION (WIDTH): 150mm
DIMENSION (HEIGHT): 99mm
DIMENSION (DEPTH): 85mm
WEIGHT: 300g
PRODUCER: B&R
PRODUCER CODE: X20CP1483